Heat transfer and flow characteristics of automotive brazed aluminum heat exchangers

Y. J. Chang*, Chi-Chuan Wang, W. J. Chang

*Corresponding author for this work

研究成果: Conference article同行評審

38 引文 斯高帕斯(Scopus)

摘要

Extensive experiments on the heat transfer and pressure-drop characteristics of automotive brazed aluminum heat exchangers were carried out. In the present study, 18 samples of louvered-fin heat exchangers with different geometrical parameters, including tube width, louver length, louver pitch, fin height, and fin pitch, were tested in an induced open wind tunnel. Results are presented as plots of friction factor and Colburn j-factor against Reynolds number based on the volumetric hydraulic diameter in the range of 200 to 1,600. The comparisons between the Sahnoun and Webb model and the present test data are reported and good agreement was found. By introducing a finning factor, a simpler correlation of the Colburn j-factor is obtained. The heat transfer data for the Colburn j-factor are correlated within 10%, and those for the friction factor are within 15%.

原文English
頁(從 - 到)643-652
頁數10
期刊ASHRAE Transactions
100
發行號2
出版狀態Published - 1 十二月 1994
事件Proceedings of the ASHRAE Annual Meeting - Orlando, FL, USA
持續時間: 25 六月 199429 六月 1994