Simultaneous Sampling of Gas- and Aerosol-Phase TDI with a Triple Filter System

Chuen-Tinn Tsai*, Kai Chung Cheng, Shankar G. Aggarwal, Tung Sheng Shih, I. Fu Hung

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

A new triple filter system sampler/model is proposed for the precise and accurate simultaneous sampling and determination of gas- and aerosol-phase 2,4-toluene diisocyanate (TDI). The system consists of two front Teflon filters for sampling aerosol-phase TDI and a final coated glass fiber filter to collect gas-phase TDI. The aerosol-phase TDI is collected on the first Teflon filter, while the second Teflon filter is used to estimate gaseous TDI adsorbed by the first. According to the gas adsorption test of two Teflon filters in series, the TDI gas adsorption fraction of the two filters is almost the same. Results of the evaporation test using pure TDI aerosols collected on the Teflon filter show that significant evaporation of the compound does not occur during sampling. These two findings allow the use of a model to estimate accurate gasand aerosol-phase TDI concentrations. The comparison test with an annular denuder shows that the triple filter system can minimize the TDI sampling bias between the dual filter and the annular denuder systems.

Original languageEnglish
Pages (from-to)1265-1272
Number of pages8
JournalJournal of the Air and Waste Management Association
Volume53
Issue number10
DOIs
StatePublished - 1 Jan 2003

Fingerprint Dive into the research topics of 'Simultaneous Sampling of Gas- and Aerosol-Phase TDI with a Triple Filter System'. Together they form a unique fingerprint.

Cite this