An automatic method to determine mitral annular lines from 2D + 1D precordial echocardiogram

Y. S. Liu, Yu-Tai Ching, S. J. Chen

Research output: Contribution to journalConference articlepeer-review

1 Scopus citations

Abstract

We present a method to determine the sequence of mitral annular lines in 2D + 1D precordial echocardiogram. We first use the optical flow technique a 2-means algorithm to determine a set of possible mitral annular points. A pair of mitral annular points could form the mitral annular line. The problem to determine the sequence of mitral annular lines in 2D + 1D echocardiogram is modeled as a problem to find the shortest path in a graph. The proposed method need very few user inputs. Experimental results show that we can find accurate mitral annular lines.

Original languageEnglish
Pages (from-to)1717-1719
Number of pages3
JournalAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Volume3
DOIs
StatePublished - 1 Dec 2000
Event22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society - Chicago, IL, United States
Duration: 23 Jul 200028 Jul 2000

Keywords

  • Combinatorial optimization
  • Left ventricle
  • Mitral annular line
  • Optical flow
  • Precordial echocardiography
  • Single-adaptive filter

Fingerprint Dive into the research topics of 'An automatic method to determine mitral annular lines from 2D + 1D precordial echocardiogram'. Together they form a unique fingerprint.